Hydra Electrical Panel for Pump and Spotlights led Transformer 100w
Hydra Electrical Panel for Pump with transformer 100W for swimming pool pump.
Comparison of range
*Scroll horizontally to view full table
HYDRA07 | HYDRA08 | HYDRA15 | HYDRA16 | HYDRA19 | HYDRA20 | |
---|---|---|---|---|---|---|
Polycarbonate Enclosure | 170x190x120 IP65 | 170x190x120 IP65 | 375x245x145 IP65 | 375x245x145 IP65 | 250x250x140 IP65 | 250x250x140 IP65 |
Supply voltage | 230 VAC 2 poles | 230 VAC 2-pole | 230 VAC 2-pole | 230 VAC 2-pole | 230 VAC 2-pole | 230 VAC 2-pole |
Equipment protection | Bipolar differential 40A high sensitivity 30mA | Bipolar differential 40A high sensitivity 30mA | Bipolar differential 40A high sensitivity 30mA | Bipolar differential 40A high sensitivity 30mA | Bipolar differential 40A high sensitivity 30mA | Bipolar differential 40A high sensitivity 30mA |
Pump protection | Motor protection adjustable in intensity, according to power. | Motor protection adjustable in intensity, according to power. | Motor guard adjustable in intensity, according to power. | Motor guard adjustable in intensity, according to power. | Motor guard adjustable in intensity, according to power. | Motor guard adjustable in intensity, according to power. |
Regulation | 4 - 6,3A | 6,3-10A | 4 - 6,3A | 6,3-10A | 4 - 6,3A | 6,3-10A |
Power | 3/4 - 1 HP | 1.5 - 2 HP | 3/4 - 1 HP | 1.5 - 2 HP | 3/4 - 1 HP | 1.5 - 2 HP |
Pump control | Manual operation by means of external selector. Automatic operation by 24h timer |
Manual operation by means of external selector. Automatic operation by 24h timer |
Manual operation by means of external selector. Automatic operation by 24h timer |
Manual operation by means of external selector. Automatic operation by 24h timer |
Manual operation by means of external selector. Automatic operation by 24h timer |
Manual operation by means of external selector. Automatic operation by 24h timer |
Transformer | - | - | Safety shielded 300VA 230 AC. Output 12V AC | Shielded safety transformer 300VA 230 AC. Output 12V AC | Toroidal 100VA 230 AC. Output 12V AC | Toroidal 100VA 230 AC. Output 12V AC |
Spotlight protection | - | - | 10A circuit breaker in primary. | 10A circuit breaker in primary. | Fuse crystal 5x20, 4a, in primary. | Glass fuse 5x20, 4a, in primary. |
Maneuver spotlights | - | - | Two-position switch. | Two-position switch. | Two-position switch. | Two-position switch. |
Warranty information
3 years from the manufacturer according to Royal Decree Law 7/2021 of April 27th.
-