Poolex Jetline Selection heat pump
The Jetline Selection heat pump with high performance and reference for swimming pool heat pumps, has a new technology of the Twisted Tech exchanger with braided titanium coil, thanks to which the water temperature rises even faster. It is available in 10 power ratings, ranging from 5.5 to 31 kW, and is suitable for pools up to 160 m3.
Manuals
Technical Data Poolex Jetline Selection Heat Pump
Poolex Jetline Selection Heat Pump Installation Manual
Poolex Jetline Selection heat pump
Thanks to a high performance compressor and a new double titanium spiral heat exchanger, it achieves a COR higher than 6 in 26/26* conditions.
Its design and its large hydrophilic aluminum evaporation surface allow the Poolex Jetline Selection to operate down to -5°C.
Easy to use, the Poolex Jetline Selection features an LCD control panel with Touch & Go technology.
Thanks to the new TwistedTech heat exchanger technology with braided coil, the water temperature rises even faster.
This pump model is available in 10 power ratings, ranging from 5.5 to 31 kW, and is suitable for pools up to 160 m3.
Advantages:
- Poolex anti-gel technology.
- Compact design.
- High performance compressor.
- Automatic defrosting by cycle inversion.
- Automatic temperature control.
- Compatible with salt treatment.
- Twisted© Tech titanium heat exchanger.
*Optional Wifi module
Accessories:
- Maintenance box including user manual in several languages.
- PVC connectors Ø 50mm 1" ½".
- Set of anti-vibration mounts.
- Cable extension (10m).
- Condensation evacuation tube.
- Protective sheath.
Warranty:
- Heat pump: 2-year warranty.
- Compressor: 5-year warranty.
- Titanium spiral: 15-year warranty against corrosion.
*Scroll horizontally to view the complete table.
Model | Jetline Selection 55 | Jetline Selection 70 | Jetline Selection 95 | Jetline Selection 125 | Jetline Selection 150 | Jetline Selection 180 | Jetline Selection 180 Tri | Jetline Selection 260 Tri | Jetline Selection 310 Tri | ||
---|---|---|---|---|---|---|---|---|---|---|---|
Model | PC-JLSS55 | PC-JLSS70 | PC-JLS095 | PC-JLS125 | PC-JLSS150 | PC-JETLINE-S180 | PC-JETLINE-S180T | PC-JETLINE-S260T | PC-JETLINE-S310T | ||
Pool volume (m3) | 20-30 | 30-40 | 40-50 | 45-65 | 65-80 | 75-95 | 75-95 | 100-135 | 120-160 | ||
Condition*: Air 26°C Water 26°C Humidity 80%. |
Capacity (W) | 5.350 | 7.040 | 9.860 | 12.750 | 15.440 | 18.060 | 18.100 | 26.240 | 31.160 | |
Power consumption (W) | 904 | 1.153 | 1.560 | 2.010 | 2.420 | 2.830 | 2.830 | 4.280 | 5.090 | ||
COR | 5,92 | 6.12 | 6.32 | 6.34 | 6.38 | 6.36 | 6.4 | 6.13 | 6.12 | ||
Condition**: |
Capacity (w) | 4.050 | 5.040 | 7.140 | 9.210 | 11.330 | 13.020 | 13.150 | 18.050 | 22.030 | |
Power consumption (W) | 810 | 1.030 | 1.410 | 1.810 | 2.200 | 2.590 | 2.600 | 3.540 | 4.310 | ||
COR | 4.97 | 4.89 | 5.06 | 5.09 | 5.13 | 5.02 | 5.05 | 5.09 | 5.11 | ||
Power supply | Mono 230V/50Hz | Mono 230V/50Hz | Mono 230V/50Hz | Mono 230V/50Hz | Mono 230V/50Hz | Mono 230V/50Hz | Tri 380x415V 3N - 50Hz | Tri 380x415V 3N - 50Hz | Tri 380x415V 3N - 50Hz | ||
Maximum power (W) | 1.350 | 1.850 | 2.380 | 2.780 | 3.530 | 3.860 | 4.530 | 6.820 | 8.220 | ||
Maximum current (A) | 6.29 | 8.43 | 10.63 | 12.56 | 15.43 | 18.10 | 7.01 | 10.34 | 12.70 | ||
Heating temperature range | 15°C / 40°C | 15°C / 40°C | 15°C / 40°C | 15°C / 40°C | 15°C / 40°C | 15°C / 40°C | 15°C / 40°C | 15°C / 40°C | 15°C / 40°C | ||
Operating range | -5°C / 43°C | -5°C / 43°C | -5°C / 43°C | -5°C / 43°C | -5°C / 43°C | -5°C / 43°C | -5°C / 43°C | -5°C / 43°C | -5°C / 43°C | ||
Flow rate (m3/h) | 1.91 | 2.52 | 3.43 | 4.22 | 5.1 | 5.9 | 5.9 | 8.1 | 10.2 | ||
Refrigerant | R32 | R32 | R32 | R32 | R32 | R410A | R410A | R410A | R410A | ||
Packaging dimensions (mm) | 922x380x740 | 922x380x740 | 950x410x786 | 950x410x786 | 950x410x786 | 950x410x786 | 950x410x786 | 1270x500x985 | 1270x500x985 | ||
Dimensions (mm) | 895x370.5x610 | 895x370.5x610 | 930x376x649 | 930x376x649 | 930x376x649 | 930x376x649 | 930x376x649 | 1220x440x950 | 1220x440x950 | ||
Net/gross weight (kg) | 39 / 48.5 | 43 / 52.5 | 50/60 | 55/56 | 60/70 | 65/75 | 68/78 | 107/122 | 112/127 | ||
Noise at 1 m (dB(A)) | <47 | <48 | <48 | <49 | <49 | <50 | <50 | <51 | <51 | ||
Noise at 4 m (dB(A)) | <37 | <38 | <38 | <39 | <39 | <40 | <40 | <41 | <41 | ||
Noise at 10 m (dB(A)) | <28 | <29 | <29 | <30 | <30 | <31 | <31 | <32 | <32 | ||
Compressor type | Rotary | Rotary | Rotary | Rotary | Rotary | Rotary | Rotary | Scroll | Scroll | ||
Compressor brand | Toshiba | Toshiba | Toshiba | Toshiba | Toshiba | Toshiba | Mitsubishi | Daikin | Daikin | ||
Heat exchanger | Double titanium spiral | Titanium double spiral | Titanium double spiral | Titanium double spiral | Titanium double spiral | Twisted Tech© titanium | Twisted Tech© titanium | Twisted Techn© titanium | Twisted Techn© titanium | ||
Function | automatic / heating / cooling | ||||||||||
Loss on load (mCE) | 0.8 | 0.91 | 1 | 1.1 | 1.2 | 1.22 | 1.22 | 1.21 | 1.21 |
* in conditions Air 26°C, Water 26°C and Humidity 80% certified by TÜV
** European Standard in conditions Air 15°C, Water 26°C and Humidity 70% certified by TÜV
Attention
Piscinas Ferromar recommends a previous thermal study to determine the equipment and power that best suits your pool and needs, taking into account the location, pool use, desired temperature, etc. To do so, please contact us at info@piscinasferromar.com and we will send you the most suitable solution. If you choose to purchase the heat pump without prior thermal study, Piscinas Ferromar is not responsible for its performance to suit the specific needs of the customer and the installation. Important: heat pumps require outdoor installation and must be installed and commissioned by a professional.-
Blue Connect & Salt Analyzer€249.00
-
Typhoon Supreme 4 Duo cleaner€890.00